Blood Collection Tube

来源:seebio.cn作者:西宝生物人气:-发表时间:2012-03-26 14:39:09【
  

Product

Product Description

 Usage

Image

Plain Tube

Color Code: Red
Specifications: ?13x75mm, ?13x100mm,?16x100mm
General Sampling Dosage: 2ml, 3ml, 4ml, 5ml, 6ml, 7ml
Maximum Vacuum Tolerance: ±10%
Packing:1200pcs/ctn
Tube material:Glass or PET

Plain Tube is used in blood collection and storage for biochemistry, immunology and serology tests in medical inspection.

It can provide enough and non-polluted serum specimen for clinical test, while keeping the serum invariable in the long inspection period.

Pro-Coagulation Tube

Color Code: Red

Specifications: ?13x75mm, ?13x100mm,?16x100mm
Normal Sampling Dosage: 2ml, 3ml, 4ml, 5ml, 6ml, 7ml
Maximum Vacuum Tolerance: ±10%
Packing:1200pcs/ctn
Tube material:Glass or PET

Pro-coagulation Tube is used in blood collection and storage for biochemistry and immunology tests.
Its main merit is that it’s uitable for a wide range of operation, fast in coagulation, and free from both secondary separation of fibrin protein and the cracking of blood corpuscle.
 

 

Gel Clot Activator Tube

Color Code: Yellow

Specifications: ?13x75mm, ?13x100mm,?16x100mm

Normal Sampling Dosage: 2ml, 3ml, 4ml, 5ml, 6ml

Maximum Vacuum Tolerance: ±10%

Packing:1200pcs/ctn

Tube material:Glass or PET

Gel & Clot Activator Tube is used for clinical biochemistry and immunology.

Inside the tube there is a barrier gel present at the bottom, which is a pure substance, very stable in physical and chemical features. After centrifugation, the barrier can effectively separate the serum from fibrin and cells, while preventing substance exchange between blood cell and serum.

As a result, it can keep biochemical characters and chemical components of serum unchanged for a long time. 

 

Glucose Tube

Product Description 

Color Code: Gray

Specifications: ?13 x75mm,?13 x100mm

Normal Sampling Dosage: 2ml, 3ml, 4ml, 5ml

Maximum Vacuum Tolerance: ≤5%

Packing:1200pcs/ctn

Tube material:Glass or PET

Glucose Tube is used in blood collection and anticoagulation for the analyses such as blood sugar, sugar tolerance, anti-alkali haemoglobin and sugar water. It is available with different additives, sodium fluoride/potassium oxalate and sodium fluoride/ammonium fluoride/potassium oxalate. Owing to the first use of special stabilizer and surface treatment inside the tube,glucose tube successfully solves the unavoidable hemolysis and prevents the occurrence of insoluble and anti-coagulant substances.

 

PT Tube

Color Code: Blue

Specifications: ?13x75mm

General Sampling Dosage: 1.8ml, 2.7ml

Maximum Vacuum Tolerance: ±5%

Tube material:Glass (1.84.5ml)or PET(1.83.6ml)

PT Tube is mainly used for the test of blood coagulation mechanism. It is filled with buffered tri-sodium citrate solution, and citrate concentrations of either 0.109mol/l (3.2%) or 0.129mol/l (3.8%) are available.
The choice of the concentration depends upon the policies of the laboratories. Care for that soon after blood sampling,mixing it 5-6 times by turning the tube 180°.

Heparin Tube

Color Code: Green

Specifications: ?13x75mm, ?13xl00mm

General Sampling Dosage: 2ml, 3ml, 4ml, 5ml, 6ml, 7ml

Maximum Vacuum Tolerance: ±10%

Packing:1200pcs/ctn

Tube material:Glass or PET

Heparin Tube is used in blood collection and anti-coagulation not only for routine clinical biochemistry tests and emergency biochemistry tests but also for some test items in blood rheology. It is coated with heparin lithium or heparin sodium . The anticoagulant heparin activates antithrombins,thus blocking the coagulation cascade and producing a whole blood/ plasma sample instead of clotted blood plus serum. Soon after the sampling, turn the tube 180°upside down,shaking and mixing 5-6 times.Heparin Anti-coagulation Blood sample should be used within 6 hours after sampling, otherwise, the blood will coagulate again.

ESR Tube

Color Code: Black

Specifications: ?8x120mm

General Sampling Dosage: 1.6ml

Maximum Vacuum Tolerance: ≤5%

Packing:1200pcs/ctn

Tube material:Glass

ESR Tube is used in blood collection and anticoagulation for sedimentation rate test. It contains a 3.8% buffered tri-sodium citrate solution (0.129mol/l) with the mixing ratio of 1 part citrate solution to 4 parts blood.
ESR measurement refers to the Westergren method. Sampling the blood dosage as required to ensuring the test accuracy

ESR Tube

Color Code: Black

Specifications: ?13x75mm ?13x100mm

Normal Sampling Dosage: 2ml, 3ml, 4ml, 5ml

Maximum Vacuum Tolerance: ≤5%

Packing:1200pcs/ctn

Tube material:Glass or PET

ESR Tube is used in blood collection and anticoagulation for sedimentation rate test. It contains a 3.8% buffered tri-sodium citrate solution (0.129mol/l) with the mixing ratio of 1 part citrate solution to 4 parts blood.
ESR measurement refers to the Westergren method. Sampling the blood dosage as required to ensuring the test accuracy

K2 EDTA tube

Color Code: Purple

Specifications: ?13x75mm,?13x100mm

General Sampling Dosage: 2ml, 3ml, 4ml, 5ml

Maximum Vacuum Tolerance: ±10%

Packing:1200pcs/ctn

Tube material:Glass or PET

EDTA Tube is widely used in clinical haematology as well as various kinds of blood cell test instruments.
It makes use of EDTA K2 as anticoagulant. Meanwhile, it offers a comprehensive protection for blood cell, especially for protecting the blood platelet, so that it can effectively stop the gathering of blood platelet and makes the form and volume of blood cell uninfluenced in a long time. EDTA tube can be used in direct sampling analyzers without actually being opened. 

K3 EDTA Tube

Color Code: Purple

Specifications: ?13x75mm,?13x100mm

General Sampling Dosage: 2ml, 3ml, 4ml, 5ml

Maximum Vacuum Tolerance: ±10%

Packing:1200pcs/ctn

Tube material: Glass or PET

EDTA Tube is widely used in clinical haematology as well as various kinds of blood cell test instruments.

It makes use of  EDTA K3 as anticoagulant. Meanwhile, it offers a comprehensive protection for blood cell, especially for protecting the blood platelet and makes the form and volume of blood cell uninfluenced in a long time. EDTA tube can be used in direct sampling analyzers without actually being opened.   

Micro tube

The micro blood collection tube considerably applies to babies. The tubes are required to be absolutely sealed with caps on so that the blood specimen could be safely transported without leaking. The side of the pipe orifice is designed to be gibbous in order to make the blood drawing more easier. With graduation,blood drawing volum can be clearly seen and controlled. We have particularly processed the inside wall to ensure smoothness. According to different requirement, additives are sprayed in the tubes evenly, which will make the mixing and anticoagulation easier and more thoroughly.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Seebio Biotech, Inc.
11-502. Lane 299, Bisheng Rd.
Zhangjiang High Tech Park
Shanghai 201204, P.R.China
Tel: 86-21-50272975, 76, 77, 78, 79, 81,Ext:6513,6515,6516,6520,6521,6522
For customers' complaint or suggestion:market5@seebio.cn
Web: www.seebio.cn
Email:fyland@seebio.cn
MSN:seebio8@hotmail.com  
Skype:seebiocn
 

西宝生物官网二维码 西宝生物微信服务号:iseebio 西宝生物微博:seebiobiotech
官网:www.cxbio.com 微信服务号:iseebio 微博:seebiobiotech
西宝商城二维码 mall.seebio.cn 微信订阅号:seebiotech 泉养堂官网:www.canmedo.com
商城:mall.seebio.cn 微信订阅号:seebiotech 泉养堂:www.canmedo.com
此文关键字:Blood Collection Tube